Solid insulation vacuum

    Product Description              

Now all of the world is considering environmental protection issues,so if SF6 is considered not environmentally friendly, you can use solid material.

And technical requirement can reach SF6‘s level.And already passed E2 level.

 
Technical Parameter
ITEM UNIT VALUE
Rated voltage KV 12
Power frequency withstand voltage(Phase to Phase、Phase to earth)  KV 42
Power frequency withstand voltage(Across isolating distance) KV 48
Lighting impulse withstand voltage(Phase to Phase、Phase to earth)  KV 75
Lighting impulse withstand voltage(Across isolating distance) KV 85
Rated frequency Hz 50/60
Rated current A 360.1250
Rated short-circuit breaking current KA 20/25
Rated short time withstand current(4S) KA 20/25
Rated peak withstand current KA 50.63
Rated short-time making current KA 50.63
Partial discharge
PC
10
Internal arc test KA 20(0.5S-1S)
Electrical endurance   E2
Operate sequence  
0-0.3s-CO-
180s-CO

 

 

 

Usage Environment

 

1.Altitude:Less than 3000m(The most 5000m)

2.ambient temperature:-40℃--40℃,The average daily temperature is not higher than 35°C

3.verage daily relative humidity:95%    Monthly average relative humidity: 90% 

  Daily average saturated vapor pressure: ≤2.2×10-3Mpa Monthly average saturated vapor pressure: ≤1.8×10-3Mpa

4.Earthquake intensity: no more than 8 degrees

5.Horizontal acceleration: synthetic seismic wave 0.25g, sinusoidal resonance beat wave 0.15g

6.Low temperature and cold area: no SF6 gas application, no need to consider the low temperature operation of SF6 gas, and it can operate normally at -45C.

7.Plateau area: no need to consider the influence of plateau atmospheric pressure on insulation performance

8.Strong wind and sand area: The safety protection level of the solid insulation ring main unit is IP67, and the control circuit room adopts special treatment to ensure long-term operation in strong wind and sand areas.

9.Coastal wet areas: epoxy resin sealing, anti-moisture, anti-salt spray corrosion, to ensure long-term use in coastal areas. Areas with high environmental protection requirements: The impact of SF6 gas on atmospheric warming has been highly regarded, and the solid ring main unit has eliminated SF6 gas, which does not cause any pollution and harm to the environment and people.

 

    Picture              
For more product details, click to download PDF to view!

Download

- News

What does solid insulated switchgear consist of?

Solid insulated switchgear is a special type of switchgear that uses solid ...

How is the insulation performance of solid insulated switchgear achieved?

Solid insulated switchgear mainly uses epoxy resin as the main insulating m...

Types of high voltage grounding switch and considerations

The high voltage grounding switch is usually part of the disconnecting swit...

What is the difference between an air circuit breaker (ACB) and a vacuum circuit breaker (VCB)?

An air switch, also known as an air circuit breaker, is a type of circuit b...

GET A QUOTE

Get in Touch

Captcha Code
×